Watchguard Home Alarm System Series II Document: Watch Guard V2.2.doc Release: 27 February 2007 Instructions Designed in Australia an

Seite 2 - Contents

10 2.4. The Power Supply Inside Roof WallPower Supply Mounting 1. Drill a small hole (15mm diameter) into the ceiling where the wire can go throu

Seite 3

11 Figure 6 2.5.1. Tips for positioning • This detector utilises the very latest in detection processing technology to reduce the possibility o

Seite 4 - 1. Introduction

12 simultaneous transmission back to the receiver in your Watchguard Home Alarm System. The receiver can only decode one coded signal at any given ti

Seite 5 - IMPORTANT NOTES

133. Operation 3.0. Master Keyswitch To operate the system, turn the key switch located beside the strobe light, to the on position. To override th

Seite 6 - 1.2. What You Get

14 3.2. AWAY Mode When to use This mode is used when leaving the building or premise, i.e. AWAY from premises. Arming the system in this mode will

Seite 7 - 2. Installation

153.5. PANIC Mode When to use This mode should be used when the user is distressed or in an emergency situation. What happens The outside siren will

Seite 8 - 2.2. The Main Unit

16 3.7. Supervision Reporting When you arm the system, you will normally hear 1 beep. If the unit continues a sequence of beeping immediately after

Seite 9 - 2.3. The Screamer

17The Red Light If the detector is set to 2 pulse counts (most sensitive) then the red light will flash if there are 2 green flashes within 10 secon

Seite 10 - 2.5. The Detectors

18 3.8.4. Dual Edge Sensing (DES) technology ‘explained’ Figure 9 – side view, detection pattern in optimal temperature environment This detector

Seite 11 - 2.5.1. Tips for positioning

19 TOP VIEW = infrared beam zone 3 Triggering the detector whenset to “least sensitive”(Default setting) Figure 11 – least sensitive trigger In fi

Seite 12 - IMPORTANT

2 Contents Contents ... 2 1.

Seite 13 - 3. Operation

20 3 Triggering the detector whenset to “most sensitive” Figure 13 – most sensitive trigger In figure 13, a body moving from position 1 to positio

Seite 14 - 3.3. STAY Mode

21 3.8.6. Low Battery Warning If the detector has near flat batteries, then on a valid movement detection the red light will flash 6 times in a row

Seite 15 - 3.6. Low Battery Reporting

22 4. Programming Ensure that before any programming, each step should be well rehearsed. This will eliminate becoming confused and making mistakes.

Seite 16 - 3.7. Supervision Reporting

23 4.1. Adding New Remotes + TO ADD A NEW REMOTE 1. Press 1 time Disarm the system (if it is not already disarmed) with an original remote co

Seite 17

24 4.2. Safety Lock Safety lock is a feature, which prevents accidental changes to the programming of the system. Safety Lock must be turned off to

Seite 18

25 4.3. Adding a Detector + TO ADD A DETECTOR 1. Safety Lock must be off Ensure Safety Lock has been turned off within the last 5 minutes. See

Seite 19

26 TO ADD A DETECTOR …continued… 6. Within 60 seconds Within 60 seconds Within 60 seconds Press to add in STAY & AWAY modes OR Press to add

Seite 20 - 2 No trigger body movements

27 4.4. Deleting a Detector TO DELETE A DETECTOR 1. Safety Lock must be off Ensure Safety Lock has been turned off within the last 5 minutes. See

Seite 21 - 3.8.7. Supervision

28 4.5. Walk Test Mode- Walk test mode should be used when testing the system or after a new detector has been learnt into the system. TO ENTER WA

Seite 22 - 4. Programming

294.6. Alarm Memory This feature is used after the alarm has been triggered. It recalls the last 10 zones which have triggered the alarm. TO HEAR

Seite 23 - 4.1. Adding New Remotes

35.2. The Remote Control ... 35 5.3. The Detector ...

Seite 24 - 4.2. Safety Lock

30 4.7. Stay Mode Entry Guard Sound This selects the type of sound you would like for the stay mode alarm. There are 2 options. Normally, if the

Seite 25 - 4.3. Adding a Detector

31 TO CHANGE THE STAY MODE ENTRY GUARD SOUND…continued… 5. Within 30 seconds Within 30 seconds Press to choose Entry Guard Tones OR Press to cho

Seite 26

32 4.8. Arm / Disarm Beeps Arming and disarming beeps can be programmed in one of the following configurations. Default BOTH ON Option 1 Arming Bee

Seite 27 - 4.4. Deleting a Detector

33 4.9. Resetting the System This will restore all settings to default. It will delete all remotes and detectors from the system. This should be d

Seite 28 - 4.5. Walk Test Mode

34 5. Maintenance The complete system should be tested at regular intervals. We suggest testing it once every fortnight or at least once per month.

Seite 29 - 4.6. Alarm Memory

355.2. The Remote Control The batteries in the remote control will need to be replaced every 1 to 3 years, depending on usage. You are able to reco

Seite 30

36 5.3.2. Cleaning the pyro detector The pyro detector must be clean at all times for optimum performance. If the pyro detector appears to have any

Seite 31 - …continued…

376. Warranty 6.1. Warning Limitations & Warranty While this system is an advanced design security system, it does not offer guaranteed protec

Seite 32 - 4.8. Arm / Disarm Beeps

38 is muffled by noise from a stereo, radio, air conditioner or other appliances, or by passing traffic. Finally, alarm warning devices, however loud

Seite 33 - 4.9. Resetting the System

39NOTE: In addition to the warranty conditions, warranty will not be given where a product has been immersed in water under any circumstances, or whe

Seite 34 - 5. Maintenance

4 1. Introduction Your Watchguard Home Alarm System is a state-of-the-art wireless security system, specifically designed for simple DIY installatio

Seite 35 - 5.3. The Detector

40 PLEASE CUT OUT & RETURN THIS INFORMATION WITHIN 14 DAYS OF PURCHASE TO: RhinoCo Pty. Ltd. 9 Hannabus Place McGraths Hill NSW 2756  Watchguar

Seite 36

51.1. The Passive Infrared Detector The detector is a high quality infrared body movement detector, which is battery operated and communicates with

Seite 37 - 6. Warranty

6 1.2. What You Get Below is a list of parts included with system. Item Description Quantity Image 1. Main control unit 1 The unit incorpora

Seite 38

7 2. Installation 2.1. Planning the Installation Each separate component of the Watchguard Home Alarm System should be placed in strategic location

Seite 39

8 2.2. The Main Unit Mount the Watchguard main unit at the front or front side of the building. The mounting position should be under an eave or ou

Seite 40

9 2.3. The Screamer Inside Roof CeilingMounting the Screamer 1. Drill a hole (15mm diameter) into the ceiling where you want to mount the scream