Watchguard™ Sentinel
Wireless Alarm System
Model: WGLCA
Document: Watchguard Sentinel – User Manual.doc
Release: 23 January 2009
U s e r M a n u a l
Designed in Australia & Made in Taiwan By:
www.rhino.com.au
Seitenansicht 0
1 2 3 4 5 6 ... 22 23

Inhaltsverzeichnis

Seite 1 - Wireless Alarm System

Watchguard™ Sentinel Wireless Alarm System Model: WGLCA Document: Watchguard Sentinel – User Manual.doc Release: 23 January 2009 U s

Seite 2 - Contents

10 • Mount the detector on your wall using the swivel mount provided at a minimum height of 1.2 metres and maximum of 2.1 metres (lower

Seite 3 - 1. Introduction

11 2.4.2. Powering the detector When you first remove the detector from the box it is not powered, although the batteries are in pl

Seite 4 - 1.1. What You Get

12 3. Operation 3.0. Turning the system on The system is automatically turned on when the power plug is connected and switched on. On power up the s

Seite 5 - IMPORTANT NOTES

13 3.3. DISARMING When to use The system should be disarmed before entering the building or premise. Indications The siren will beep twice and the b

Seite 6 - 2. Installation

14 This detector has Dual Edge Sensing (DES) Technology, developed to eliminate false alarms yet still provide maximum security. The detect

Seite 7 - 2.2. The Main Unit

15 Triggering the detector Figure 10 – most sensitive trigger In figure 10, a body moving from position 1 to position 2, into the infrared be

Seite 8 - 2.3. The Power Supply

16 4. Programming Turning the unit off and on enters programming mode. On each instance of programming mode only a single device may be

Seite 9 - 2.4. The Detector

17 4.2. Adding a Detector + TO ADD A DETECTOR 1. Turn the system off, from the power supply or unplug. Wait 10 seconds. 2.

Seite 10

18 5. Maintenance The complete system should be tested at regular intervals. We suggest testing it once every fortnight or at least once per month.

Seite 11 - I M P O R T A N T

19 When replacing the batteries you must take the following into consideration: • You must replace both batteries at the same time. Don’t just repl

Seite 12 - 3. Operation

2 Contents Contents ... 2 1. Introduction ...

Seite 13 - 3.4. PANIC Mode

20 6. Warranty 6.1. Warning Limitations & Warranty While this system is an advanced design security system, it does not offer gua

Seite 14

21 • Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers who are located on the other side of clo

Seite 15

22 less of cause or origin, seller's maximum liability shall not in any case exceed the purchase price of the product, which shall be the comple

Seite 16 - 4. Programming

23 PLEASE CUT OUT & RETURN THIS INFORMATION WITHIN 14 DAYS OF PURCHASE TO YOUR LOCAL OFFICE: RhinoCo Technology Head Office: 9 Hannabus Place, M

Seite 17 - 4.2. Adding a Detector

3 1. Introduction Your Watchguard Sentinel Home Alarm System is specifically designed for simple DIY installation (Do It Yourself). I

Seite 18 - 5. Maintenance

4 1.1. What You Get Below is a list of parts included with system. Item Description Quantity Image 1. Main control unit The unit incorporates

Seite 19

5 1.2. The Passive Infrared Detector (PIR) The detector is a high quality infrared body movement detector, which is battery operated an

Seite 20 - 6. Warranty

6 2. Installation 2.1. Planning the Installation Each separate component of the Watchguard Sentinel Home Alarm System should be placed in

Seite 21

7 2.2. The Main Unit Mount the Watchguard main unit at the front or front side of the building. The mounting position should be under an eave or ou

Seite 22

8 2.3. The Power Supply Power Supply Mounting Inside Roof Wall Figure 4 1. Drill a small hole (15mm diameter) into the ceiling where the wire c

Seite 23

9 2.4. The Detector Firstly, the mounting bracket must be fixed to the wall using the self-tapping screw and other accessories supplied. Mou